Siemens 11208702 - Immunoassay Reagent / Calibrator Kit Advia Centaur® CP Thyroid-Stimulating Hormone (TSH) Ultra II CLIA Non-Waived For Advia Centaur CP System 500 Tests - 1/Box
- The ADVIA Centaur® TSH3‑Ultra II (TSH3ULII) assay is for in vitro diagnostic use in the quantitative determination of thyroid-stimulating hormone (TSH, thyrotropin) in human serum and plasma (EDTA and lithium heparin) using the ADVIA Centaur® CP system
- Measurements of thyroid stimulating hormone produced by the anterior pituitary are used in the diagnosis of thyroid or pituitary disorders
- This assay is a third-generation assay that employs FITC-labeled mouse monoclonal anti‑TSH antibody and mouse monoclonal anti‑fluorescein antibody linked to paramagnetic particles, an FITC-labeled anti‑TSH capture mouse monoclonal antibody, and a tracer consisting of a proprietary acridinium ester and an anti‑TSH mouse monoclonal antibody conjugated to bovine serum albumin (BSA) for chemiluminescent detection
This product can be found in our Diagnostics -> Clinical Laboratory -> Laboratory Equipment -> Clinical Analyzers and Accessories -> Reagents section.
- SKU
- 100-1253539BX
Description / Siemens 11208702 - Immunoassay Reagent / Calibrator Kit Advia Centaur® CP Thyroid-Stimulating Hormone (TSH) Ultra II CLIA Non-Waived For Advia Centaur CP System 500 Tests - 1/Box
This Siemens Advia Centaur CP kit contains the immunoassay reagents and calibrator for Thyroid-Stimulating Hormone (TSH) Ultra II testing. It is made for the Advia Centaur CP System. It is a CLIA non-waived product and is sold as one box.
- Immunoassay reagent and calibrator kit for Thyroid-Stimulating Hormone (TSH) Ultra II
- CLIA non-waived
- Made for use with the Advia Centaur CP System
- 500 tests per kit
- Serum or plasma sample type
- Supplied as a pack and vial container type
- Volume: R1: 6 mL, R2: 21 mL, R3: 6 mL, Cal: 4 X 2 mL
- Siemens manufacturer number 11208702
Check that your analyzer is the Advia Centaur CP System before ordering.
More Information
| Unit Of Measure | Box |
|---|---|
| Country Of Origin | United States |
| Buy American Act (BAA) Compliant | No |
| Trade Agreement Act (TAA) Compliant | Yes |
| UNSPSC Code | 41116004 |
| Product Notice | License Required |
| Manufacturer Name | Siemens |
| Manufacturer Number | 11208702 |
| Application | Immunoassay Reagent / Calibrator Kit |
| Brand Or Series | Advia Centaur® CP |
| Qty Per Unit of Measure | 1 |
| Container Type | Pack / Vial |
| For Use With | For Advia Centaur CP System |
| Volume | R1: 6 mL, R2: 21 mL, R3: 6 mL, Cal: 4 X 2 mL |
| Number Of Tests | 500 Tests |
| Sample Type | Serum / Plasma Sample |