Atila BioSystems Inc GHPVF-100 - Molecular Reagent AmpFire Human Papillomavirus (HPV) High Risk Genotyping For Research Use Only For Real Time PCR Instrument 100 Tests - 1/Kit
- The AmpFire HPV High Risk Genotyping is an in vitro nucleic acid isothermal amplification with real time fluorescence detection assay for the qualitative genotyping of high-risk Human Papillomavirus (HPV) genotypes 16, 18, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68 from different sample types
- Cervical specimens that may be tested with the Atila AmpFire HPV High Risk Genotyping assay include dry cervical swab, PreservCyt Solution (using an aliquot that is removed prior to or after processing for the PreservCyt Pap test), BD SurePath Preservative Fluid (using an aliquot that is removed prior to or after processing for the BD SurePath Pap test and formalin-fixed paraffin-embedded (FFPE) tissue specimens
- Assay requires 1 hour of instrument time
This product can be found in our Diagnostics -> Clinical Laboratory -> Laboratory Equipment -> Clinical Analyzers and Accessories -> Reagents section.
- SKU
- 100-1281148KT
Description / Atila BioSystems Inc GHPVF-100 - Molecular Reagent AmpFire Human Papillomavirus (HPV) High Risk Genotyping For Research Use Only For Real Time PCR Instrument 100 Tests - 1/Kit
The AmpFire HPV High Risk Genotyping reagent is a molecular reagent from Atila BioSystems Inc. It is labeled for research use only. It is made for use with a real time PCR instrument.
- Molecular reagent for Human Papillomavirus (HPV) high risk genotyping
- For research use only
- Made for use with a real time PCR instrument
- Contains 100 tests
- Sample type: rectal / vaginal swab sample
- Brand: AmpFire, manufactured by Atila BioSystems Inc
- Manufacturer number: GHPVF-100
Check that your lab uses a real time PCR instrument and rectal or vaginal swab samples before ordering.
More Information
| Unit Of Measure | Kit |
|---|---|
| Buy American Act (BAA) Compliant | No |
| Trade Agreement Act (TAA) Compliant | No |
| UNSPSC Code | 41116020 |
| Manufacturer Name | Atila BioSystems Inc |
| Manufacturer Number | GHPVF-100 |
| Application | Molecular Reagent |
| Brand Or Series | AmpFire |
| Qty Per Unit of Measure | 1 |
| For Use With | For Real Time PCR Instrument |
| Number Of Tests | 100 Tests |
| Sample Type | Rectal / Vaginal Swab Sample |
More in This Series
| Product |
|---|
| Atila BioSystems Inc GHPVF-100 - Molecular Reagent AmpFire Human Papillomavirus (HPV) High Risk Genotyping For Research Use Only For Real Time PCR Instrument 100 Tests - 1/Kit (this item) |
| Atila BioSystems Inc MHPVF1618-100 - Molecular Reagent AmpFire Human Papillomavirus (HPV) Screening 16/18/HR For Research Use Only For Real Time PCR Instrument 100 Tests - 1/Kit |